Two lines do most of the work on a peptide Certificate of Analysis: purity, usually by HPLC, and identity, often by LC-MS. They answer different questions. Purity asks how much of what the instrument detected is the main compound. Identity asks whether that main compound is the right molecule. You want both.
What HPLC Measures
HPLC stands for high-performance liquid chromatography. The testing laboratory prepares a small portion of the sample and pumps it, carried in a liquid called the mobile phase, through a narrow column packed with fine particles. Different components interact with that packing differently, so they leave the column at different times.
A detector at the end records a trace called a chromatogram, and each component shows up as a peak. For peptides the detector is usually ultraviolet, which is the “UV” in “HPLC-UV.” It’s often set near 214 nm, a wavelength where peptide bonds absorb light. Some reports spell out the setup, for example reversed-phase HPLC (RP-HPLC) at 214 nm.
How a Purity Percentage Is Calculated
The common approach is called area percent. The lab measures the area under every peak, then divides the main peak’s area by the total. If the main peak accounts for 99.5% of the total area, the report reads 99.5%.
That number is useful, and it has limits worth knowing:
- It only counts what the detector can see at that wavelength. A component that doesn’t absorb there won’t appear.
- Two components that leave the column at the same moment can merge into a single peak.
- It doesn’t measure quantity. Water and counter-ions, the salts peptides commonly carry, aren’t part of the figure, so purity alone says nothing about how many milligrams are in the vial.
That last point is why the net content or quantitative assay line matters. Purity and content are separate results, and it’s worth checking that a COA reports both.
What LC-MS Adds
LC-MS pairs liquid chromatography with mass spectrometry. After separation, molecules are ionized and the instrument measures their mass-to-charge ratio. From that, the lab works out the molecular mass of the main component and compares it with the theoretical mass calculated from the compound’s structure.
When the two agree, the report reads “Confirmed.” Mass is a far more specific fingerprint than a UV peak. A truncated sequence, a missing amino acid or an entirely different compound would usually show a different mass.
LC-MS/MS goes a step further. It breaks the molecule into fragments and measures those as well, which gives information about sequence, not just total mass. A plain mass match can’t always tell apart two molecules built from the same atoms in a different order. Fragment data helps close that gap.
Other Identity Methods You’ll See
Not every COA uses mass spectrometry. Some report “Qualitative ID (Lambda Max): Matches,” meaning the wavelength where the sample absorbs UV light most strongly matched the reference. Alongside it you may see “Quantitative Assay (Beer-Lambert),” which calculates the amount present from how much light the sample absorbs.
These are standard spectroscopic checks. They’re less specific than a mass match, so it helps to know which one you’re reading before you compare two reports.
Where to Find These Results in Our Catalog
Products with a published COA show the results on the product page under the Certificate of Analysis tab. At the time of writing, several list identity by LC-MS, including Selank (10mg), CJC-1295 Without DAC (10mg) and PNC-27 (10mg). Others, such as NAD+ (500mg), report a qualitative ID alongside a quantitative assay, heavy metals and microbial counts.
Each posted COA has a Download PDF button, so you can keep the full report with your records.
A Simple Reading Order
When you open any COA, read it in this order: the lot and test date, then identity and its method, then purity and its method, then net content against the amount on the label. If identity isn’t confirmed, nothing below it matters much.