Blog › Quality & Testing

How to Read a Certificate of Analysis, Line by Line

Updated

A Certificate of Analysis, or COA, is a short report from a testing laboratory about one specific lot of a compound. It answers a few plain questions. What was tested? When, and by whom? What did the results show?

At Clean Chain Labs, products with a published COA show it on the product page under the Certificate of Analysis tab. It’s public, so you can read it before you open an account. Here’s how to read one from top to bottom.

Start at the Top: Lot, Date and Laboratory

The first three lines tell you what the rest of the report describes.

  • Lot. The batch identifier for the material that was tested. Every result below applies to this lot, not to the compound in general.
  • Tested. The date the laboratory ran the analysis.
  • Laboratory. The name and street address of the lab that produced the report.

If any of those are missing, the document is hard to rely on. A purity figure with no lot attached could describe any batch, made at any time.

Identity: Is It the Right Compound?

Check identity first. A purity number means little if the main component isn’t the compound on the label. On the COAs in our catalog, identity shows up in a few forms:

  • Identity (LC-MS): Confirmed. The measured molecular mass matched the expected mass for that compound.
  • Qualitative ID (Lambda Max): Matches. The wavelength where the sample absorbs ultraviolet light most strongly matched the reference for that compound.
  • Identity: Confirmed or Conforms, sometimes with the compound name printed beside it.

Mass spectrometry is the most specific of these. If the report names a method, note it, because it tells you how the identity call was made.

Purity: Read the Method Next to the Number

Purity is the number most people look at first. Read the label beside it before you read the figure. “Purity (HPLC-UV)” means the result comes from HPLC, a liquid chromatography method, read with an ultraviolet detector. It’s the share of the detected signal that belongs to the main compound, given as a percentage.

Some COAs list purity under a different method, shown as “Percent Purity (Correlation Coefficient).” A few show two figures, an original result and a conformity result. Different methods measure different things, so 99.3% by one method and 99.3% by another aren’t quite the same statement.

Net Content: How Much Is in the Vial

Purity tells you what share of the material is the target compound. Net content tells you how much material the lab measured. Depending on the report, this line is labeled Net Content, Quantitative Assay or Content, and it’s given in milligrams.

Compare it with the amount printed on the label. Measured values rarely land exactly on the label figure, and the COA shows you where this particular lot came in. For multi-component products, such as the BPC-157 / TB-500 Blend (10mg / 10mg), the report gives a separate net content line for each component.

Microbial and Heavy Metal Results

Many reports include contamination screens. Microbial Analysis (PCR) looks for microbial DNA and reads Pass or No Detectable Microbial DNA. TAMC and TYMC stand for total aerobic microbial count and total yeast and mold count, reported in colony-forming units, or CFU.

Heavy metals are reported in parts per billion (ppb). A result such as “<10 ppb” means the level was below 10 ppb, the lowest figure that test reports.

Match the Report to Your Vial

Every vial we ship is labeled with the compound, the amount, the lot number and a research-use-only statement. When your order arrives, compare the lot on the label with the lot on the COA tab. Each posted COA has a Download PDF button, so you can save the full report with your records for that lot.

When a Product Has No COA Tab

Not every item in the catalog has a posted COA. Where one is posted, it sits on the product page, and the Specifications tab includes a Documentation line. If a product you’re considering has no COA tab, send us a product question before you order.

See One for Yourself

The easiest way to learn this is to open a real report. The BPC-157 (10mg) Certificate of Analysis shows the lot, test date, laboratory, identity, HPLC purity, net content and microbial result in one table. From there, browse the shop and check the COA tab on anything you plan to order.

For Research Use Only — Not for Human Use.

Browse the Catalog

Every product page shows its price and volume pricing, no account needed to look.

Shop Peptides